Agilent/Keysight N9020A MXA Signal Analyzer, 10 Hz to 26.5 GHz

ID:201491123313172
Brand:Agilent/HP
Model:N9020A
Unit:UNIT
Size:
Contact Sales:Contact Sales

Description

The N9020A MXA is designed to accelerate the development of new wireless devices for quick delivery to manufacturing and the marketplace. It has the versatility to easily adapt to your evolving test requirements by addressing multiple formats, generations and devices.

Real-time spectrum analyzer capability can be added as an upgrade to new and exisiting MXAs to help you capture and understand the most elusive signals in an increasingly complex signal environment. Coupled with 160 MHz of wideband analysis bandwidth, the MXA allows you to make accurate analysis of next-generation wireless communications and connectivity signals.

The N9020A MXA signal analyzer is a member of the X-Series spectrum analyzers, which is an evolutionary approach to signal analysis that spans instrumentation, measurements and software. It gives you the flexibility to satisfy your business and technical requirements across multiple products and programs - now and in the future.

Key Features & Specifications

Functionality - See the latest enhancements

  • 10 Hz to 3.6, 8.4, 13.6, or 26.5 GHz; extend frequency to 110 GHz with Keysight's smart mixers and up to 1.1 THz with other vendors' mixers
  • 25 MHz (standard); 40, 85, 125 or 160 MHz analysis bandwidth
  • Fast sweep capability ships standard on new instruments equipped with Option B40, DP2, or MPB; fast power measurements available as Option FP2
  • Real-time spectrum analyzer capabilities with 100% probability of intercept for signal duration as short as 3.57 µs

Performance

  • ±0.23 dB absolute amplitude accuracy
  • -114 dBc/Hz phase noise at 10 kHz offset; +20 dBm third order intercept (TOI)
  • -166 dBm displayed average noise level (DANL) with preamplifier and get up to 9 dB further improvement with noise floor extension (Option NFE)
  • -78 dB W-CDMA ACLR dynamic range (with noise correction on)

Measurement applications & software

  • Supports >25 measurement applications, covering cellular communication, wireless connectivity, digital video and general purpose
  • Advanced analysis of more than 75 signal formats, software runs inside the MXA with 89600 VSA software
  • MATLAB data analysis software for general purpose data analysis, visualization, and measurement automation.
  • Keysight's PowerSuite one-button power measurements included as standard

Automation & communication interface

 

 

N9020A-1CM
Rack mount kit 

Rack mount kit

N9020A-1CM
  • Adds rackmount flanges to the analyzer
  • Fits standard 482.6 mm (19 inch) rack
  • Occupies four units (177.8 mm) of rack space
  • Can be added as a product upgrade
N9020A-1CN
Front handle kit 

Front handle kit

N9020A-1CN
  • Adds front handles to the instrument
  • Can be added as a product upgrade
N9020A-1CP
Rackmount and handle kit 
N9020A-1CR
Rack slide kit 

Rack slide kit

N9020A-1CR
  • Adds rack slides to the analyzer
  • Fits standard Keysight racks
  • Includes slide assembly and mounting hardware
  • Can be added as a product upgrade
N9020A-503
Frequency range, 10 Hz to 3.6 GHz 

Frequency range, 10 Hz to 3.6 GHz

N9020A-503
  • 10 Hz to 3.6 GHz
  • 3.6 GHz internal preamplifier (optional)
  • Available at time of purchase only
N9020A-508
Frequency range, 10 Hz to 8.4 GHz 

Frequency range, 10 Hz to 8.4 GHz

N9020A-508
  • 10 Hz to 8.4 GHz
  • 3.6 or 8.4 GHz internal preamplifier (optional)
  • Available at time of purchase only
N9020A-513
Frequency range, 10 Hz to 13.6 GHz 

Frequency range, 10 Hz to 13.6 GHz

N9020A-513
  • 10 Hz to 13.6 GHz
  • 3.6, 8.4 or 13.6 GHz internal preamplifier (optional)
  • Available at time of purchase only
N9020A-526
Frequency range, 10 Hz to 26.5 GHz 

Frequency range, 10 Hz to 26.5 GHz

N9020A-526
  • 10 Hz to 26.5 GHz
  • 3.6, 8.4, 13.6 or 26.5 GHz internal preamplifier (optional)
  • Available at time of purchase only
N9020A-A6J
ANSI Z540-1-1994 Calibration 

ANSI Z540-1-1994 Calibration

N9020A-A6J
  • Unit ships directly from the factory with ANSI Z540 calibration
  • Provides measurement results, uncertainties and specifications
  • The uncertainties are not included in the determination of pass/fail status
  • Available at time of purchase only
N9020A-AB2
Hard Copy of X-Series Chinese Getting Started and Troubleshooting Guide 

Hard Copy of X-Series Chinese Getting Started and Troubleshooting Guide

N9020A-AB2
  • Hard copy of the getting started and troubleshooting guide in Chinese
  • Order as N9020A-AB2 (part number N9020-90170)
  • Can be added as a product upgrade
N9020A-AKT Getting Started Guide MXA Russian Localization
N9020A-AMG
Calibration + Uncertainties + Guardbanding (Accredited) 
N9020A-B1A
Analysis bandwidth, 125 MHz 

Analysis bandwidth, 125 MHz

N9020A-B1A
  • Frequency range: 10 Hz to 3.6, 7, 13.6 or 26.5 GHz
  • Capture memory: 2 GB (fully accessible via 89600 VSA software or N9064A VXA application)
  • ADC Resolution: 14 bits
  • Supports real-time spectrum analyzer
  • Can be added as a product upgrade
N9020A-B1X
Analysis bandwidth, 160 MHz 

Analysis bandwidth, 160 MHz

N9020A-B1X
  • Frequency range: 10 Hz to 3.6, 7, 13.6 or 26.5 GHz
  • Capture memory: 2 GB (fully accessible via 89600 VSA software or N9064A VXA application)
  • ADC Resolution: 14 bits
  • Supports real-time spectrum analyzer
  • Can be added as a product upgrade
N9020A-B25
Analysis Bandwidth, 25 MHz 

Analysis Bandwidth, 25 MHz

N9020A-B25
  • Standard on N9020A MXA signal analyzers
  • Frequency range: 10 Hz to 3.6, 8.4, 13.6 or 26.5 GHz
  • Capture Memory: 2 GB (fully accessible via 89600 VSA software or N9064A VXA application)
  • ADC Resolution: 16 bits
  • Can be added as a product upgrade
N9020A-B40
Analysis bandwidth, 40 MHz 

Analysis bandwidth, 40 MHz

N9020A-B40
  • Frequency range: 10 Hz to 3.6, 8.4, 13.6, or 26.5 GHz
  • Capture memory: 2 GB (fully accessible via 89600 VSA software or N9064A VXA application)
  • ADC resolution: 12 bits
  • Can be added as a product upgrade
N9020A-B85
Analysis bandwidth, 85 MHz 

Analysis bandwidth, 85 MHz

N9020A-B85
  • Frequency range: 10 Hz to 3.6, 7, 13.6 or 26.5 GHz
  • Capture memory: 2 GB (fully accessible via 89600 VSA software or N9064A VXA application)
  • ADC Resolution: 14 bits
  • Supports real-time spectrum analyzer
  • Can be added as a product upgrade
N9020A-BAG Accessory Pouch
N9020A-BBA
I/Q baseband inputs, analog 

I/Q baseband inputs, analog

N9020A-BBA
  • Adds analog baseband I/Q inputs with 500 Msa deep capture standard memory
  • Input impedance: Selectable 50 ohm and 1 Mohm
  • Baseband bandwidth: 10 MHz standard and optional 25 MHz or 40 MHz
  • Baseband capture memory: 500 MSamples (2GB) standard
  • Can be added as a product upgrade
N9020A-CR3
Connector, Wideband IF output 

Connector, Wideband IF output

N9020A-CR3
  • Adds wideband IF output to the signal analyzer
  • IF out = 322.5/250 MHz dependent on IF BW Option 25/40
  • Frequency of IF is dependent on the IF path as stated in the key specifications
  • Can be added as a product upgrade
N9020A-CRP
Connector,programmable rear IF output 

Connector,programmable rear IF output

N9020A-CRP
  • Adds programmable IF output to the signal analyzer
  • Frequency of the IF output is adjustable from 10 to 75 MHz, in 500 kHz steps
  • IF output bandwidth is 100 MHz nominal at 70 MHz center frequency
  • Connector type: SMA (female), 50 ohm impedance nominal
  • Can be added as a product upgrade
N9020A-DP2
Digital Processor, 2 GB Capture Memory 

Digital Processor, 2 GB Capture Memory

N9020A-DP2
  • Digital processor with extended capture memory to 2 GB
  • Improves IQ acquisition speed, especially with high sample rate
  • 25 MHz analysis bandwidth (standard)
  • Cannot be added as a product upgrade
N9020A-DVR
DVD-ROM/CD-R/RW Drive 

DVD-ROM/CD-R/RW Drive

N9020A-DVR
  • Connect to the USB 2.0 ports on the front or rear panel of the MXA
  • Access DVD or CD media from the MXA´s Microsoft® Windows interface
  • Can be added as a product upgrade
N9020A-EA3
Electronic attenuator, 3.6 GHz 

Electronic attenuator, 3.6 GHz

N9020A-EA3
  • Frequency range: 20 Hz to 3.6 GHz
  • Step size: 1 dB
  • Range: 0 to 24 dB
  • Full range including mechanical attenuation: 94 dB
  • Can be added as a product upgrade
N9020A-EDP
Enhanced display package license 

Enhanced display package license

N9020A-EDP
  • Spectrogram – Time, amplitude, frequency & delta markers
  • Trace Zoom – Both traces are active (lower trace is subset of upper trace)
  • Zone Span – One trace updated at a time, independent BWs, point & sweep time
  • Can be added as a product upgrade
N9020A-EMC
Basic EMC functionality license 

Basic EMC functionality license

N9020A-EMC
  • CISPR 16-1-1 (2010) fully-compliant detectors
  • CISPR band presets to 18 GHz
  • Measure at marker with three detectors
  • Tune and Listen for signal discrimination
  • Can be added as a product upgrade
N9020A-ESC
External source control license 

External source control license

N9020A-ESC
  • Controls Keysight signal generators up to 26.5 GHz
  • Provides choice of hardware triggering or software triggering
  • Sweep modes: standard, harmonic, offset, reverse, & power
  • Can be added as a product upgrade
N9020A-EXM
External mixing 

External mixing

N9020A-EXM
  • Capable of analyzing signals up to 110 GHz
  • Frequency coverage can be extended up to 1.1 THz with other vendor’s mixers
  • Amplitude corrections for conversion loss
  • Signal identification
  • Mixer biasing
N9020A-FP2
Fast Power, up to 40 MHz bandwidth 

Fast Power, up to 40 MHz bandwidth

N9020A-FP2
  • Enables hardware accelerated fast power measurement capability
  • 40 MHz single acquisition bandwidth
  • Optimized for power measurements such as Channel Power, Adjacent Channel Power, Occupied Bandwidth and Harmonic measurements
N9020A-HTC
Hard Transit Case 

Hard Transit Case

N9020A-HTC
  • Roller handle, wheels for storage/transportation of your analyzer
  • Weight: 20 kg (45 lbs) empty or 36 kg (80 lbs) with analyzer
  • Dimensions: H 42.6 cm (16.8 in) W 68.5 cm (27 in) L 73.6 cm (29 in)
  • Can be added as a product upgrade
N9020A-KB2 US 65 Key USB Keyboard
N9020A-KYB Keyboard, USB
N9020A-MLP
Minimum Loss Pad, 50 to 75 ohm 

Minimum Loss Pad, 50 to 75 ohm

N9020A-MLP
  • Converts analyzer to 75 ohm input
  • Connector: 50 ohm type-N (m) to 75 ohm BNC (f) connector
  • Frequency range: 9 MHz to 2 GHz
  • Insertion loss: 5.7 dB, typical
  • Can be added as a product upgrade
N9020A-MPB
Microwave preselector bypass 

Microwave preselector bypass

N9020A-MPB
  • Bypasses microwave preselector for improved IF bandwidth
  • Excellent wideband amplitude flatness & phase linearity
  • Option MPB recommended for use with wideband analysis, Option B40
  • Upgrade an existing MXA by ordering N9020AK-HL4
N9020A-NFE
Noise floor extension 

Noise floor extension

N9020A-NFE
  • License key enabled and provides up to 10 dB of improvement in analyzer noise floor
  • Available on all MXA frequency models
N9020A-P03
Preamplifier, 3.6 GHz 

Preamplifier, 3.6 GHz

N9020A-P03
  • Enhances analyzer's detection of low-level signals
  • Frequency range: 100 kHz to 3.6 GHz
  • Gain: +20 dB
  • Noise figure: 11 dB
  • DANL with preamp: -166 dBm
  • Can be added as a product upgrade
N9020A-P08
Preamplifier, 8.4 GHz 

Preamplifier, 8.4 GHz

N9020A-P08
  • Enhances analyzer’s detection of low-level signals
  • Frequency range: 100 kHz to 8.4 GHz
  • Gain: +35 dB
  • Noise figure: 9 dB (3.6 GHz to 8.4 GHz)
  • DANL with preamp: -166 dBm (3.6 GHz to 8.4 GHz)
  • Can be added as a product upgrade
N9020A-P13
Preamplifier, 13.6 GHz 

Preamplifier, 13.6 GHz

N9020A-P13
  • Enhances analyzer’s detection of low-level signals
  • Frequency range: 100 kHz to 13.6 GHz
  • Gain: +35 dB
  • Noise figure: 10 dB (8.4 GHz to 13.6 GHz)
  • DANL with preamp: -165 dBm (3.6 GHz to 13.6 GHz)
  • Can be added as a product upgrade
N9020A-P26
Preamplifier, 26.5 GHz 

Preamplifier, 26.5 GHz

N9020A-P26
  • Enhances analyzer’s detection of low-level signals
  • Frequency range: 100 kHz to 26.5 GHz
  • Gain: +35 dB
  • Noise figure: 15 dB (13.6 GHz to 26.5 GHz)
  • DANL with preamp: -157 dBm (20 GHz to 26.5 GHz)
  • Can be added as a product upgrade
N9020A-PFR
Precision frequency reference 

Precision frequency reference

N9020A-PFR
  • Enhances frequency reference performance & stability
  • Temperature stability: 1.5x10-8 (2x10-6 standard)
  • One year aging rate: 1x10-7 (1x10-6 standard)
  • Residual FM: 0.25 Hz x N p-p in 20ms (10 Hz x N p-p in 20 ms standard)
  • Can be added as a product upgrade
N9020A-PRC
Portable Configuration 

Portable Configuration

N9020A-PRC
  • Adds rubber protective corners and end guards
  • Adds pivoting carrying handle
  • Handle mounted on the sides
  • Can be added as a product upgrade
N9020A-RT1
Real-time analysis up to 160 MHz BW, basic detection license 

Real-time analysis up to 160 MHz BW, basic detection license

N9020A-RT1
  • >15 µs minimum signal duration for 100% probability of frequency mask triggering
  • Up to 160 MHz real-time analysis bandwidth
  • Frequency mask trigger
  • Seamlessly integrates with 89600 VSA software
  • Can be added as a product upgrade
N9020A-RT2
Real-time analysis up to 160 MHz BW, optimum detection license 

Real-time analysis up to 160 MHz BW, optimum detection license

N9020A-RT2
  • 100% probability of intercept: 3.57 µs
  • Up to 160 MHz real-time bandwidth
  • Frequency mask trigger
  • Seamlessly integrates with 89600 VSA software
  • Can be added as a product upgrade
N9020A-RTR
Real-time spectrum recorder and analyzer application example 

Real-time spectrum recorder and analyzer application example

N9020A-RTR
  • Real-time spectrum recorder and analyzer application example
  • Modifiable application and source code -allows user to customize or extend the application or analysis routines for specific testing needs
  • MATLAB software (MATLAB and Instrument Control Toolbox) to execute or modify this application
     
N9020A-S40 Baseband bandwidth, 40 MHz/Channel
N9020A-SF2
Security features, prohibit saving results 

Security features, prohibit saving results

N9020A-SF2
  • License key enabled and provides additional security features to prohibit saving results
  • Supported on all X-Series signal analyzers with software version A.14.00 and greater
N9020A-SSD
Additional removable solid state drive 

Additional removable solid state drive

N9020A-SSD
  • Additional removable solid state drive
  • Removable bay with min 1,500 insertion cycles
  • Fully imaged with operating system, software, and alignment files
  • Can be added as a product upgrade
N9020A-UK6
Commercial calibration certificate with test data 

Commercial calibration certificate with test data

N9020A-UK6
  • Commercial calibration performed by the Keysight factory
  • Printed copy of the calibration certificate
  • Instructions to download a PDF of the test data report from Infoline
N9020A-W7X Operating system, Windows Embedded Standard 7
N9020A-YAS
Y-axis ouptut 

Y-axis ouptut

N9020A-YAS
  • Output screen video through the analog output port on the rear panel of the signal analyzer
  • Operate in spectrum analyzer mode only
  • Connector type: BNC (female), 50-ohm impedance nominal
  • Can be added as a product upgrade
1CM013A
Rackmount Flange Kit 177.0mm H (4U) - Two Flange Brackets 

Rackmount Flange Kit 177.0mm H (4U) - Two Flange Brackets

1CM013A
Two flange brackets
N6141A
EMI Measurement Application 

EMI Measurement Application

N6141A
  • Supports latest CISPR 16-1-1 or MIL-STD detectors & bandwidth
  • Perform radiated & conducted emissions measurements
  • Compare measured emissions to regulatory limits
N6141A-2FP EMI measurement application, fixed perpetual license
N6141A-2TP EMI measurement application, transportable perpetual license
N6149A
IDEN/WIDEN/MotoTalk Measurement Application 

IDEN/WIDEN/MotoTalk Measurement Application

N6149A
  • Standard-based iDEN power, iDEN demod, MotoTalk demod & vector analysis BTS/MS measurements
  • Key tests: BER, EVM, PvT
  • Carrier configurations: 25/50/75/100/50-outer kHz
  • Modulation formats supported: 4QAM/16QAM/64QAM
N6149A-2FP IDEN, WIDEN, Moto Talk Measurement application, fixed perpetual license
N6149A-2TP IDEN/WIDEN/MotoTalk measurement application, transportable perpetual license
N6152A
Digital Cable TV Measurement Application 

Digital Cable TV Measurement Application

N6152A
  • J.83/A (DVB-C), J.83/B (DOCSIS DS), J.83/C (ISDB-C) standards
  • Transmit RF & analog baseband measurements with BBIQ hardware
  • 1-button measurements with standard pass/fail & default settings
N6152A-2FP DVB-C/J.83 Annex A/C measurement application, fixed perpetual license
N6152A-2TP DVB-C/J.83 Annex A/C measurement application, measurement application, transportable perpetual license
N6152A-3FP J.83 Annex B measurement application, fixed perpetual license
N6152A-3TP J.83 Annex B measurement application, transportable perpetual license
N6152A-MEU
Minor enhancement update, fixed perpetual license 

Minor enhancement update, fixed perpetual license

N6152A-MEU
  • Latest enhancements to the Digital Cable TV measurement application for X-Series signal analyzers
N6153A
DVB-T/H/T2 Measurement Application 

DVB-T/H/T2 Measurement Application

N6153A
  • DVB-T/H/T2 measurements; T2 option supports Mode A & B, SISO, MISO
  • R&D manufacturing of modulators, transmitters, components
  • 1-button measurements with pass/fail per standard
N6153A-2FP DVB-T/H Measurement application, fixed perpetual license
N6153A-2TP DVB-T/H measurement application, transportable perpetual license
N6153A-3FP DVB-T2 measurement application, fixed perpetual license
N6153A-3TP DVB-T2 measurement application, transportable perpetual license
N6155A
ISDB-T/Tmm Measurement Application 

ISDB-T/Tmm Measurement Application

N6155A
  • ISDB-T, ISDB-TB, ISDB-TSB, & ISDB-Tmm standards
  • Transmit RF & analog baseband measurements with BBIQ hardware
  • 1-button measurements with pass/fail per the standard, plus auto detection
N6155A-2FP ISDB-T Measurement Application,fixed perpetual license
N6155A-2TP ISDB-T measurement application , transportable perpetual license
N6155A-3FP ISDB-Tmm, Measurement Application, fixed perpetual license
N6155A-3TP ISDB-Tmm, measurement application, transportable perpetual license
N6156A
DTMB (CTTB) Measurement Application 

DTMB (CTTB) Measurement Application

N6156A
  • Supports DTMB (CTTB) standard of multi-carrier & single-carrier
  • Transmit RF & analog baseband measurements with BBIQ hardware
  • 1-button measurements with pass/fail per standard
N6156A-2FP DTMB (CTTB) measurement application, fixed perpetual license
N6156A-2TP DTMB (CTTB) measurement application, transportable perpetual license
N6158A
CMMB Measurement Application 

CMMB Measurement Application

N6158A
  • Supports CMMB standard
  • Transmit RF & analog baseband measurements with BBIQ hardware
  • 1-button measurements with pass/fail per the standard & auto detection
N6158A-2FP CMMB Measurement Application,fixed perpetual license
N6158A-2TP CMMB measurement application, transportable perpetual license
N6171A
MATLAB Software 

MATLAB Software

N6171A
  • Create arbitrary waveforms
  • Customize measurement/data analysis routines, instrument applications/test systems
  • Automate measurements, signal generation, report generation
  • Available directly from Keysight with purchase of compatible instrument
N6171A-M01
MATLAB-Basic Package, individual license - node-locked 

MATLAB-Basic Package, individual license - node-locked

N6171A-M01
  • Basic configuration includes:
  • MATLAB software environment
  • Instrument Control Toolbox
N6171A-M02
MATLAB-Standard Package, individual license - node-locked 
N6171A-M03
MATLAB-Advanced Package, individual license - node-locked 

MATLAB-Advanced Package, individual license - node-locked

N6171A-M03
  • Advanced MATLAB configuration includes:
  • MATLAB software environment
  • Instrument Control Toolbox
  • Communications Toolbox
  • Signal Processing Toolbox
  • DSP System Toolbox
  • RF Toolbox
N9051A
Pulse Measurement Software 

Pulse Measurement Software

N9051A
  • Analyze ≤1,000 continuous pulses at once, ≤200,000 statistically
  • Multi-view for concurrent analysis: power, frequency, or phase vs. time, power vs. frequency
  • PRI/PRF, pulse width, duty cycle, rise/fall, droop, overshoot, ripple, statistical analysis
N9051A-2FP Pulse measurement software, fixed perpetual, license
N9051A-2TP Pulse measurement software, fixed, transportable perpetual license
N9051A-3FP Phase and frequency measurements, fixed perpetual license
N9051A-3TP Phase and Frequency Measurements, transportable perpetual license
N9051A-4FP Extended analysis and statistics, fixed perpetual license
N9051A-4TP Extended Analysis and Statistics, transportable perpetual license
N9061A
Remote Language Compatibility Application 

Remote Language Compatibility Application

N9061A
  • Emulate HP/Keysight 856xE/EC or 8566/8568 spectrum analyzers in remotely controlled, ATE systems
  • Migrate 856xE/EC-based or 8566/8568-based ATE systems to seamlessly include a modern signal analyzer
N9061A-1FP Remote language compatibility, 8566/68, fixed perpetual license
N9061A-2FP Remote language compatibility, 856xE/EC, fixed perpetual license
N9062A
SCPI Language Compatibility 

SCPI Language Compatibility

N9062A
  • Emulate remote FSP/FSU/FSE analyzer or ESU EMI receiver operation for common basic spectrum analyzer function commands
  • Match data format from trace queries to FSP/FSU/FSE/ESU for common data formats
N9062A-2FP Remote language compatibility, R&S FSP, fixed perpetual license
N9063A
Analog Demodulation Measurement Application 

Analog Demodulation Measurement Application

N9063A
  • Display modulation metrics: AM depth, FM/PM deviation, THD, SINAD, FM Stereo
  • Analyze analog modulated signals with a selection of detectors: Peak+, Peak-, (Pk-Pk)/2 & RMS
  • Play the modulating signal over a speaker
N9063A-2FP Analog Demodulation Measurement application, fixed perpetual license
N9063A-2TP Analog demodulation measurement application, transportable perpetual license
N9063A-3FP FM stereo measurement application, fixed perpetual license
N9063A-3TP FM stereo measurement applications, transportable perpetual liense
N9064A
VXA Vector Signal Analysis Measurement Application 

VXA Vector Signal Analysis Measurement Application

N9064A
  • FFT-based spectrum analysis
  • Time-domain analysis tools for burst analysis
  • General-purpose analog & digital modulation analysis
N9064A-1FP
Vector signal analysis application, VXA, fixed perpetual license 

Vector signal analysis application, VXA, fixed perpetual license

N9064A-1FP
Option 1FP (replacement for 89601X Option 205 and Option 333) analyzes the frequency, time, and amplitude domain behavior of your signal.
N9064A-1TP Vector signal analysis application, VXA, transportable perpetual license
N9064A-2FP
Flexible digital modulation analysis measurement application, fixed perpetual license 
N9064A-2TP Flexible digital modulation analysis measurement application, fixed transportable license
N9064A-MEU
Minor enhancement update 

Minor enhancement update

N9064A-MEU
  • Latest enhancements to the vector signal analysis measurement application for X-Series signal analyzers
N9065B Sequence analyzer measurement application
N9068A
Phase Noise Measurement Application 

Phase Noise Measurement Application

N9068A
  • 1-button measurements for analyzing phase noise in frequency domain (log plot) & time domain (spot frequency)
  • Compatible with PSA & ESA spectrum analyzer phase noise measurement personality
N9068A-2FP Phase Noise Measurement application, fixed perpetual license
N9068A-2TP Phase Noise measurement application, transportable perpetual license
N9068A-MEU
Minor enhancement update 

Minor enhancement update

N9068A-MEU
  • Latest enhancements to the phase noise measurement application for X-Series signal analyzers
N9069A
Noise Figure Measurement Application 

Noise Figure Measurement Application

N9069A
  • Noise figure/gain measurements from 10 MHz to 26.5 GHz
  • 1-button measurements include noise figure, gain, Y-factor, effective temperature, hot/cold power density
  • Supports Keysight SNS/346 Series noise sources, X-Series analyzers, MXE EMI receiver
N9069A-1FP Noise figure measurement application, fixed perpetual license
N9069A-1TP Noise figure measurement application, transportable perpetual license
N9069A-2FP Noise figure measurement application advanced features, fixed perpetual license
N9069A-2TP Noise figure measurement application advanced features, transportable perpetual license
N9069A-MEU
Minor enhancement update 

Minor enhancement update

N9069A-MEU
  • Latest enhancements to the noise figure measurement application for X-Series signal analyzers
N9071A
GSM/EDGE/Evo Measurement Application 

GSM/EDGE/Evo Measurement Application

N9071A
  • GSM/EDGE/EDGE Evo including VAMOS1 & Multi-Carrier BTS (MCBTS) per 3GPP GERAN standard
  • BTS/MS RF tx measurements; analog baseband measurements with BBIQ hardware
  • 1-button measurements with pass/fail per standard
N9071A-2FP
GSM/EDGE measurement application, fixed perpetual, license 

GSM/EDGE measurement application, fixed perpetual, license

N9071A-2FP
Option 2FP allows the GSM/EDGE application to run in the analyzer.
N9071A-2TP GSM/EDGE measurement application, transportable perpetual, license
N9071A-3FP
EDGE Evo measurement application, fixed perpetual license 

EDGE Evo measurement application, fixed perpetual license

N9071A-3FP
Option 3FP allows the EDGE Evo application to run in the analyzer.
N9071A-3TP EDGE Evo measurement application, transportable perpetual license
N9071A-MEU
Minor enhancement update 

Minor enhancement update

N9071A-MEU
  • Latest enhancements to the GSM/EDGE/Evo measurement application for X-Series signal analyzers 
N9071A-XFP
Single acquisition combined GSM/EDGE measurement application, fixed perpetual license 

Single acquisition combined GSM/EDGE measurement application, fixed perpetual license

N9071A-XFP
Option XFP single acquisition combined GSM/EDGE measurement application is a high-speed manufacturing test solution available on X-Series signal analyzers: the MXA and EXA.
N9071A-XTP GSM/EDGE combined measurement application, transportable perpetual, license
N9072A
cdma2000 Measurement Application 

cdma2000 Measurement Application

N9072A
  • Complies with 3GPP2 Release A, supports IS-95, cdmaOne, cdma2000® for forward & reverse link RF
  • Transmit RF & analog baseband measurements with BBIQ hardware
  • 1-button measurements with pass/fail per standard
N9072A-2FP cdma2000 measurement application, fixed perpetual license
N9072A-2TP cdma2000 measurement application, transportable perpetual license
N9073A
W-CDMA/HSPA+ Measurement Application 

W-CDMA/HSPA+ Measurement Application

N9073A
  • W-CDMA/HSPA/HSPA+ per 3GPP release 99 to 8
  • Uplink/downlink RF transmitter measurements
  • Transmit analog baseband measurements with BBIQ hardware
  • 1-button measurements with pass/fail per the standard
N9073A-1FP
W-CDMA Measurement application, fixed perpetual license 
N9073A-1TP W-CDMA measurement application, fixed transportable perpetual license
N9073A-2FP
HSDPA/HSUPA measurement application, fixed perpetual license 

HSDPA/HSUPA measurement application, fixed perpetual license

N9073A-2FP
Option 2FP allows the HSPA application to run in the analyzer.
N9073A-2TP HSDPA/HSUPA measurement application, transportable perpetual license
N9073A-3FP
HSPA+ Measurement Application, fixed perpetual license 

HSPA+ Measurement Application, fixed perpetual license

N9073A-3FP
Option 3FP allows the HSPA+ application to run in the analyzer.
N9073A-3TP HSPA+ measurement application, transportable perpetual license
N9073A-MEU
Minor enhancement update 

Minor enhancement update

N9073A-MEU
  • Latest enhancements to the W-CDMA/HSPA+ measurement application for X-Series signal analyzers
N9073A-XFP
Single acquisition combined W-CDMA measurement application, fixed perpetual license 

Single acquisition combined W-CDMA measurement application, fixed perpetual license

N9073A-XFP
Option XFP single acquisition combined W-CDMA measurement application is a high-speed manufacturing test solution available on X-Series signal analyzers: the MXA and EXA.
N9073A-XTP Single acquisition combined W-CDMA measurement application, transportable perpetual license
N9074A
Fixed WiMAX Single Acquisition Combined Measurement Application 

Fixed WiMAX Single Acquisition Combined Measurement Application

N9074A
  • Single acquisition combined fixed WiMAX measurement application supports IEEE 802.16-2004 modulation formats: BPSK/QPSK/16QAM/64QAM
  • Supports signal hopping for broadband/multi-frequency points measurements
  • Supported on MXA/EXA signal analyzers
N9074A-XFP Single acquisition combined WiMAX measurement application, fixed perpetual, license
N9074A-XTP Single acquisition combined WiMAX measurement application, fixed perpetual license
N9075A
Mobile WiMAX Measurement Application 

Mobile WiMAX Measurement Application

N9075A
  • 802.16 OFDMA measurements per IEEE 802.16 2005 standard
  • Transmit RF & analog baseband measurements with BBIQ hardware
  • 1-button, standard-based measurements with pass/fail tests
N9075A-2FP Mobile WiMAX measurement application, fixed perpetual, license
N9075A-2TP Mobile WiMAX measurement application, transportable perpetual, license
N9076A
1xEV-DO Measurement Application 

1xEV-DO Measurement Application

N9076A
  • Complies with 1XEV-DO 3GPP2 standard of physical layer specifications C.S0024
  • Transmit RF & analog baseband measurements with BBIQ hardware
  • 1-button pass/fail measurements per standard
N9076A-1FP 1xEV-DO measurement application, fixed perpetual license
N9076A-1TP 1xEV-DO measurement application, transportable perpetual license
N9077A
WLAN 802.11a/b/g/n/ac Measurement Application 

WLAN 802.11a/b/g/n/ac Measurement Application

N9077A
  • Compliant to 802.11a/b/g/j/p, 802.11n, & 802.11ac IEEE series standards for WLAN design/manufacturing test
  • Manual settings for 802.11j, 802.11a-turbo mode, & 802.11p
  • 1-button pass/fail measurements per standard
N9077A-2FP
WLAN 802.11a/b/g measurement application, fixed perpetual license 

WLAN 802.11a/b/g measurement application, fixed perpetual license

N9077A-2FP
Option 2FP provides one-button standard-based spectrum, time and modulation quality measurements for WLAN (802.11a/b/g) signals.
N9077A-2TP WLAN 802.11a/b/g measurement application, transportable perpetual license
N9077A-3FP
WLAN 802.11n measurement application, fixed perpetual license 

WLAN 802.11n measurement application, fixed perpetual license

N9077A-3FP
Option 3FP provides one-button standard-based spectrum, time and modulation quality measurements for WLAN (802.11n 20 MHz, 40 MHz) signals.
N9077A-3TP WLAN 802.11n, measurement application, transportable perpetual license
N9077A-4FP
WLAN 802.11ac measurement application, fixed perpetual license 

WLAN 802.11ac measurement application, fixed perpetual license

N9077A-4FP
Option 4FP provides one-button standard-based spectrum, time, and modulation quality measurements for WLAN (802.11ac 20/40/80/160 MHz and 80+80 MHz bandwidth) signals.
N9077A-4TP WLAN 802.11ac measurement application, transportable perpetual license
N9077A-5FP
WLAN 802.11 list sequence measurement application, fixed perpetual license 

WLAN 802.11 list sequence measurement application, fixed perpetual license

N9077A-5FP
Option 5FP is a breakthrough solution for automated, high-volume, high-throughput product manufacturing tests.
N9077A-5TP WLAN 802.11 list sequence measurement application, transportable perpetual license
N9079A
TD-SCDMA/HSPA Measurement Application 

TD-SCDMA/HSPA Measurement Application

N9079A
  • TD-SCDMA/TD-HSDPA/HSUPA/8PSK per 3GPP release 99 to 8
  • Uplink/downlink RF tx measurements; analog baseband measurements with BBIQ hardware
  • 1-button measurements with pass/fail per the standard
N9079A-1FP
TD-SCDMA measurement application, fixed perpetual license 

TD-SCDMA measurement application, fixed perpetual license

N9079A-1FP
Option 1FP allows the TD-SCDMA application to run in the analyzer.
N9079A-1TP TD-SCDMA measurement application, transportable perpetual license
N9079A-2FP
HSPA measurement application, fixed perpetual license 

HSPA measurement application, fixed perpetual license

N9079A-2FP
Option 2FP allows the HSPA/8PSK application to run in the analyzer.
N9079A-2TP HSPA measurement application, transportable perpetual license
N9079A-MEU
Minor enhancement update 

Minor enhancement update

N9079A-MEU
  • Latest enhancements to the TD-SCDMA/HSPA measurement application for X-Series signal analyzers
N9080A LTE FDD Measurement Application
N9080A-1FP LTE FDD measurement application, fixed perpetual license
N9080A-1TP LTE FDD measurement application, transportable perpetual license
N9080B
LTE/LTE-Advanced FDD measurement application 

LTE/LTE-Advanced FDD measurement application

N9080B
  • LTE and LTE-Advanced FDD per 3GPP release 8 to 11
  • Uplink and downlink in a single option
  • Carrier aggregation with up to five component carriers
  • Runs inside PXA, MXA and EXA signal analyzers with Windows 7 operating system (standard)
N9080B-1F1 LTE FDD measurement application, fixed timebased licenses, 1 month
N9080B-1FP
LTE FDD measurement application, fixed perpetual license 

LTE FDD measurement application, fixed perpetual license

N9080B-1FP
  • LTE-FDD per 3GPP standard
  • Downlink and uplink in a single option
  • Analysis of all LTE channels and signals
  • Runs inside PXA, MXA and EXA signal analyzers with Windows 7 operating system (standard)
N9080B-1TP LTE FDD measurement application, transportable perpetual license
N9080B-2F1 LTE-Advanced FDD measurement application, fixed timebased licenses, 1 month
N9080B-2FP
LTE-Advanced FDD measurement application, fixed perpetual license 

LTE-Advanced FDD measurement application, fixed perpetual license

N9080B-2FP
  • LTE-Advanced FDD per 3GPP Release 10/11 standard
  • Carrier aggregation of up to 5 contiguous/non-contiguous component carriers (CCs)
  • Clustered SC-FDMA and simultaneous PUCCH/PUSCH uplink analysis
  • Runs inside PXA, MXA, and EXA signal analyzers with Windows 7 operating system (standard)
N9080B-2TP LTE-Advanced FDD measurement application, transportable perpetual license
N9081A
Bluetooth Measurement Application 

Bluetooth Measurement Application

N9081A
  • Compliant with Bluetooth® Core Specification Version 2.1+ EDR & Low Energy
  • 1-button measurements with pass/fail per the standard
N9081A-2FP Bluetooth Measurement Application, fixed perpetual license
N9081A-2TP Bluetooth measurement application, transportable perpetual license
N9081A-MEU
Minor enhancement update 

Minor enhancement update

N9081A-MEU
  • Latest enhancements to the Bluetooth measurement application for X-Series signal analyzers
N9082A LTE TDD Measurement Application
N9082A-1FP LTE TDD measurement application, fixed perpetual license
N9082A-1TP LTE TDD measurement application, transportable perpetual license
N9082B
LTE/LTE-Advanced TDD measurement application 

LTE/LTE-Advanced TDD measurement application

N9082B
  • LTE and LTE-Advanced TDD per 3GPP release 8 to 11
  • Uplink and downlink in a single option
  • Carrier aggregation with up to five component carriers
  • Runs inside PXA, MXA and EXA signal analyzers with Windows 7 operating system (standard)
N9082B-1F1 LTE TDD measurement application, fixed timebased Licenses, 1 month
N9082B-1FP
LTE TDD measurement application, fixed perpetual license 

LTE TDD measurement application, fixed perpetual license

N9082B-1FP
  • LTE-TDD per 3GPP standard
  • Downlink and uplink in a single option
  • Analysis of all LTE channels and signals
  • Runs inside PXA, MXA, and EXA signal analyzers with Windows 7 operating system (standard)
N9082B-1TP LTE TDD measurement application, transportable perpetual license
N9082B-2F1 LTE-Advanced TDD measurement application, fixed timebased licenses, 1 month
N9082B-2FP
LTE-Advanced TDD measurement application, fixed perpetual license 

LTE-Advanced TDD measurement application, fixed perpetual license

N9082B-2FP
  • LTE-Advanced TDD per 3GPP Release 10/11 standard
  • Carrier aggregation of up to 5 contiguous/non-contiguous component carriers (CCs)
  • Clustered SC-FDMA and simultaneous PUCCH/PUSCH uplink analysis
  • Runs inside PXA, MXA, and EXA signal analyzers with Windows 7 operating system (standard)
N9083A
Multi-Standard Radio (MSR) Measurement Application 

Multi-Standard Radio (MSR) Measurement Application

N9083A
  • MSR per 3GPP Release 9 standard (TR/TS 37 series)
  • Tx test on LTE-FDD, W-CDMA/HSPA/HSPA+, & GSM/EDGE/EDGE Evolution signals
  • Automatic sequencing function eliminates need for the wide analysis bandwidth option
N9083A-1FP Multi-Standard Radio, MSR, measurement application, fixed perpetual license
N9083A-1TP Multi-Standard Radio, MSR, measurement application, transportable perpetual license